Test Procedure
This image is a Logic Diagram of a Booster Pump for a computer or
programmable logic controller.
- In Inspect mode the Booster Pump Starter is off.
- In Product mode the following conditions must be met before a signal is
sent to start the Booster Pump;
- The Flow Control Device is on
- The Divert Micro switch is in forward position
- The Detect Micro switch detects the forward flow, and;
- The proper Regenerator Pressures are met
- In clean in place mode, after a delay of ten minutes or more the Programmed
clean in place Operation begins. If the ten minute delay is not used than the
booster pump starter cannot be activated during clean in place.